CCHN ChemicalsChemical export sourcing from ChinaStart RFQ
Phosphorus-Free RO Antiscalant for CA/TFC Membranes sourcing visualCandidate for RFQ after document and specification verification
Back to sourcing hubWater Treatment

Phosphorus-Free RO Antiscalant for CA/TFC Membranes

Buyer-facing sourcing candidate for a phosphorus-free liquid RO antiscalant used in membrane water treatment systems. Key checks should focus on formulation identity, membrane compatibility with CA/TFC systems, pH range, specific gravity, phosphorus-free confirmation, impurity profile, packing format, SDS/TDS availability, export classification, and shipment documentation before RFQ or sample approval.

Quick buying facts

Identify the grade, package, and import market before comparing suppliers.

Use this page to check the product identity, common specification points, document scope, package notes, and destination-market questions before sending a China sourcing request.

Appearance: colorless to light yellow transparent liquidWater treatment chemical / RO membrane antiscalantCandidate for RFQ after document and specification verification
Identity and grade

Typical specifications

  • Appearance: colorless to light yellow transparent liquid
  • Form: liquid industrial water treatment agent
  • pH: 6.0-9.0, reported for 1% solution
  • Specific gravity: >=1.03
  • Formulation claim: phosphorus-free
  • Membrane compatibility claim: RO, NF, UF systems; CA and TFC membranes
  • Performance claims to verify: scale inhibition, solubility, hydrolytic stability, no insoluble compounds with iron or aluminum oxides
  • Model reference from source: SGR1513W / ProtecMBC 1513W
Who uses this page

Target buyers

  • RO antiscalant distributors
  • Water treatment chemical importers
  • Desalination plant chemical buyers
  • Industrial water treatment service companies
  • Membrane system OEMs and maintenance providers
  • Private-label water treatment chemical brands
  • Municipal and industrial wastewater treatment procurement teams
Before matching

Documents to check

  • CAS number, grade, assay, and impurity profile
  • SDS, COA, TDS, HS code, and transport classification
  • Destination-market import documents before supplier matching
Package and route

Packing notes

  • Reported standard packing: 25 kg plastic drum
  • Other reported options: 25 L, 200 L, and 1000 L plastic drums or IBC-style packing
  • Transport package listed as blue or white plastic drum
  • Bulk order packing should be confirmed by net weight, pallet configuration, drum material, seal type, and export markings
  • Sample availability, sample size, and sample documentation should be confirmed before technical evaluation
Applications and sourcing options

Check whether this product fits the buyer's actual application.

Clear application, grade, package, and document notes help separate real sourcing demand from a vague price check.

Use context

Common applications

  • Reverse osmosis membrane scale control
  • Pretreatment chemical program for CA and TFC membranes
  • Industrial circulating water treatment procurement
  • NF and UF membrane system support where supplier compatibility is verified
  • Phosphorus-reduction water treatment programs subject to discharge limits
  • Distributor sourcing for private-label antiscalant lines
How we compare

Sourcing options

  • Request technical sample with SDS, TDS, and COA before bulk RFQ
  • Ask for phosphorus-free verification and membrane compatibility documentation
  • Compare 25 kg drum, 200 kg drum, and 1000 kg IBC landed cost
  • Use third-party pre-shipment inspection for first commercial order
  • Request export packing photos, palletization plan, and shipping marks before shipment
  • Screen supplier certifications, production capacity, and batch traceability before approval
Human review

Compliance notes

  • Request current SDS, TDS, COA, label draft, and product specification before purchase
  • Confirm whether the product has a CAS number as a mixture or whether all active components are disclosed under NDA for compliance screening
  • Verify phosphorus-free claim with total phosphorus test method and acceptance limit
  • Check local import requirements for water treatment chemicals in the destination market
  • Confirm HS code, DG classification, UN number if applicable, and whether the product ships as non-dangerous goods
  • Supplier certifications listed include ISO9001:2015, ISO45001:2018, and ISO14001; request valid certificates and scope pages
  • Do not rely on platform description as a regulatory guarantee; verify documentation against destination-country requirements
Buyer search paths

Related sourcing terms

These terms support long-tail discovery while keeping the page focused on useful product and China export buying context.

RO antiscalant supplierphosphorus-free antiscalantreverse osmosis scale inhibitorCA membrane antiscalantTFC membrane antiscalantwater treatment chemical suppliermembrane scale inhibitorindustrial RO chemicalnon-phosphorus RO antiscalantRO membrane treatment chemical
RFQ questions before supplier matching

Turn this product into a quote request.

Share target market, quantity, packaging scope, artwork status, delivery destination, and required documents so CHN Chemicals can prepare a cleaner supplier comparison.

Questions to confirm
  • Can you provide current SDS, TDS, COA, product label, and full specification sheet for this RO antiscalant?
  • Is the product a registered mixture, and can you provide CAS information or component disclosure under NDA for compliance review?
  • What is the confirmed phosphorus content limit and test method for the phosphorus-free claim?
  • What are the active content range, solids content, density range, viscosity, and shelf life?
  • Is the product compatible with CA and TFC membranes from major membrane suppliers, and do you have compatibility letters or field references?
  • What impurities or restricted substances are controlled, including heavy metals, chloride, phosphate, and VOC-related parameters?
  • Can you confirm DG status, HS code, export documents, and whether ocean/air shipment is permitted as non-DG?
  • What packing options are available for export orders: 25 kg drum, 200 kg drum, 1000 kg IBC, or customized packing?
Checks before quote
  • Request current SDS, TDS, COA, label draft, and product specification before purchase
  • Confirm whether the product has a CAS number as a mixture or whether all active components are disclosed under NDA for compliance screening
  • Verify phosphorus-free claim with total phosphorus test method and acceptance limit
  • Check local import requirements for water treatment chemicals in the destination market
  • Confirm HS code, DG classification, UN number if applicable, and whether the product ships as non-dangerous goods
  • Supplier certifications listed include ISO9001:2015, ISO45001:2018, and ISO14001; request valid certificates and scope pages
  • Do not rely on platform description as a regulatory guarantee; verify documentation against destination-country requirements
Next step

Send the product page with your target quantity and market. A sourcing manager can then confirm sample options, supplier fit, packaging details, and open document gaps.