CCHN ChemicalsChemical export sourcing from ChinaStart RFQ
R407C Refrigerant Gas, 99.9% Min, Industrial Grade in Cylinders sourcing visualHuman review
Back to sourcing hubIndustrial Basics

R407C Refrigerant Gas, 99.9% Min, Industrial Grade in Cylinders

Buyer-facing sourcing profile for R407C refrigerant gas offered in disposable and refillable cylinder formats. Key checks should focus on confirmed R407C blend composition, CAS alignment, minimum purity, moisture/acidity/non-condensable gas limits, cylinder type approval, dangerous goods documentation, and destination-market restrictions on HFC refrigerants and non-refillable cylinders.

Quick buying facts

Identify the grade, package, and import market before comparing suppliers.

Use this page to check the product identity, common specification points, document scope, package notes, and destination-market questions before sending a China sourcing request.

Product: R407C refrigerant gasRefrigerant gas / HFC blend / industrial gasHuman review
Identity and grade

Typical specifications

  • Product: R407C refrigerant gas
  • Grade: Industrial / refrigeration grade
  • Purity: 99.9% min as stated by supplier
  • Blend identity: Verify full R407C composition and CAS numbers before purchase
  • Reported CAS references: 354-33-6 and 811-97-2; request confirmation of all blend components including R32/R125/R134a where applicable
  • Appearance: Colorless liquefied gas
  • Reported GWP: 1700
  • ODP: request confirmed value on COA or product datasheet
  • Reported critical temperature: 85.768 C
  • Reported critical pressure: 4.602 MPa
  • Reported molecular weight: 86.2
  • Reported boiling point discrepancy: source page shows both -26.1 C and -43.8 C; buyer should verify against datasheet and COA
Who uses this page

Target buyers

  • Refrigerant importers and distributors
  • HVAC service supply wholesalers
  • Industrial gas distributors
  • Cold chain maintenance suppliers
  • OEM and aftermarket refrigeration parts buyers
  • Regional chemical trading companies with DG import capability
Before matching

Documents to check

  • CAS number, grade, assay, and impurity profile
  • SDS, COA, TDS, HS code, and transport classification
  • Destination-market import documents before supplier matching
Package and route

Packing notes

  • Disposable cylinder options stated: 340 g, 1 kg, 3.4 kg, 6.8 kg, 13.6 kg
  • Refillable cylinder options stated: 12.3 L, 50 L, 400 L, 926 L, ISO tank
  • Reported carton loading: 20 ft container / 13.6 kg cylinders / 1150 cartons
  • Request cylinder specification, valve type, net fill weight, tare weight, hydrostatic test status, and cylinder markings
  • For non-refillable cylinders, confirm legality and acceptance in the destination market before RFQ
  • Request palletization, carton dimensions, gross weight, and container loading plan for freight quotation
Applications and sourcing options

Check whether this product fits the buyer's actual application.

Clear application, grade, package, and document notes help separate real sourcing demand from a vague price check.

Use context

Common applications

  • Commercial HVAC refrigerant supply chains
  • Refrigeration maintenance distribution
  • Industrial cooling equipment service networks
  • Aftermarket refrigerant resale where legally permitted
  • Stock replenishment for qualified refrigerant distributors
How we compare

Sourcing options

  • Standard ARKOOL-branded cylinder supply
  • OEM/private-label cylinder supply subject to MOQ and compliance review
  • Disposable small cylinder supply where legally accepted
  • Refillable cylinder supply for markets restricting disposable cylinders
  • Bulk cylinder, drum, or ISO tank sourcing for qualified industrial gas buyers
Human review

Compliance notes

  • R407C is generally treated as a regulated refrigerant/HFC product in many markets; import eligibility should be checked by buyer before order placement
  • Classify and ship as dangerous goods where applicable; request SDS, COA, DG declaration, transport classification, UN number, hazard class, packing instruction, and emergency contact information
  • Request REACH, CE, DOT, cylinder approval, and export documentation only where relevant to the destination country and package type
  • Do not rely on platform claims alone; verify manufacturer identity, export license, batch traceability, and third-party audit documents
  • Confirm whether destination market restricts HFC quota, labeling, F-gas registration, technician-use requirements, or disposable cylinder imports
  • Supplier page contains inconsistent boiling point data and incomplete CAS presentation; require written technical confirmation before procurement
Buyer search paths

Related sourcing terms

These terms support long-tail discovery while keeping the page focused on useful product and China export buying context.

R407C refrigerant gas China supplierR407C industrial gas manufacturerR407C 99.9% purity refrigerantHFC refrigerant blend supplierR407C cylinder exportrefrigerant gas disposable cylinderrefrigerant gas refillable cylinderHVAC refrigerant sourcingDG refrigerant export Chinaindustrial gas manufacturer China
RFQ questions before supplier matching

Turn this product into a quote request.

Share target market, quantity, packaging scope, artwork status, delivery destination, and required documents so CHN Chemicals can prepare a cleaner supplier comparison.

Questions to confirm
  • Can you provide the latest COA for R407C showing composition, purity, moisture, acidity, evaporation residue, and non-condensable gas values?
  • Please confirm the full R407C blend components with CAS numbers and percentage ranges.
  • Which cylinder types are available for export to our destination market, and are non-refillable cylinders permitted there?
  • Can you provide SDS, DG declaration, transport classification, cylinder certificate, and batch traceability documents before shipment?
  • What valve type, net weight, tare weight, cylinder standard, and markings are used for each packing size?
  • Can you confirm the correct boiling point and technical datasheet values for this product?
  • What is the MOQ by package size, and can mixed package sizes be loaded in one shipment?
  • What is the lead time for standard brand and OEM/private-label cylinders?
Checks before quote
  • R407C is generally treated as a regulated refrigerant/HFC product in many markets; import eligibility should be checked by buyer before order placement
  • Classify and ship as dangerous goods where applicable; request SDS, COA, DG declaration, transport classification, UN number, hazard class, packing instruction, and emergency contact information
  • Request REACH, CE, DOT, cylinder approval, and export documentation only where relevant to the destination country and package type
  • Do not rely on platform claims alone; verify manufacturer identity, export license, batch traceability, and third-party audit documents
  • Confirm whether destination market restricts HFC quota, labeling, F-gas registration, technician-use requirements, or disposable cylinder imports
  • Supplier page contains inconsistent boiling point data and incomplete CAS presentation; require written technical confirmation before procurement
Next step